SUPPLY & FIT NEW HMO WIRED FIRE ALARM SYSTEM BS5839
Aug 9th, 2010 by admin

£1420.00 inc postage

We are authorised & qualified Honeywell fire alarm Installers We offer nationwide fitting for various applications & to meet various BS STANDARDS We cover system design, Installation, Commissioning & maintenance Honeywell equipment is used in all our installations Prices may vary The price on this advert covers 1x 4 zone Honeywell control panel 9x smoke detectors 1x heat detector 3x sounders Any changes to this will need to be quoted, please email/call us Certificates are issued on completion Fire Alarm Systems fall broadly in to two groups - Conventional Systems or Analogue Addressable Systems.

‘Conventional’ Fire Alarm Systems, in their various forms, have been around for many years and have changed little in that time in terms of technology although design and reliability have improved significantly. However, Conventional fire alarm Systems are a well-proven technology protecting many hundreds of thousands of properties worldwide. A Conventional Fire Alarm System is often the natural choice for smaller systems or where budget constraints exist.

Incorporating the Multipoint detector with built-in sounder means the whole system cab be installed using only one pair of wires.

Using the Multipoint detector as part of the Twinflex 2-wire fire alarm system means that when a detector is wired in, a sounder is too - with no extra wiring. This greatly reduces the number of points that need to be installed and the time it takes to install them.

As the Multipoint offers 7 different modes of detection, the installation is made even simpler as this one device suits all applications. Whatever type of detection is required, for any part of the installation, it can be selected by the flick of a switch at the time of commissioning. Any one of the 3 different smoke modes, 2 fixed temperature heat modes, a rate of rise mode and a combination smoke or heat mode can be selected.

As the Multipoint detector is available with or without a full specification 92dBA sounder (for only a marginal cost difference) no extra devices need to be purchased when audible warning is required (meets audibilty levels recommended in BS5839 Part 1: 1988). Twinflex callpoints can be run on the same pair of wires as detectors. Further cost savings can be utilised by using the new combined callpoint / sounder. Both detectors and callpoints have a selectable EOL module so any device can be set as the end of line monitor. The panel can also differentiate between callpoint or detector alarms.

If extra sound is required, or for areas that do not require detection, then the Hatari Sounder can be used on the same two wires, offering sound output of 100dBA. It also has a built-in EOL monitoring switch.

The panel can accommodate 32 devices per zone, has separate fault monitoring displays for each zone, and a one man walk test facility. Zones are configured without the need to use resistors or capacitors on unused zones.

  • Two wire installation - only one circuit per zone to connect detectors and sounders.
  • Installation savings as high as 40% - save on cable, installation time and sounders.
  • Callpoint identification - panel can differentiate between callpoint or detector alarms.
  • Built-in end of line device - all devices including detectors, callpoints and stand-alone sounders have a selectable built-in end of line monitoring function. No resistors or extra circuits required.
  • No base diode requirement.
  • Multipoint detector provides 7 modes of detection.
  • System fully complies with BS and EN.
  • 32 devices per zone.
  • Easy to install - no need to worry about marking “in’s” and “out’s”.
  • Available with 2,4 and 8 zone panels.
  • 8 and 16 zone repeater panels available.
  • 72 hour standby.
  • Auxiliary sounder circuit.
  • Output module for plant switching, door release etc.

xenex control panels

manual calls points

detectorsbellsDoor ReleaseS-Cubed Conventional Range

Shopping Cart
Jun 7th, 2010 by admin
Your cart is empty
Y4-NEW WIRED IONISATION SMOKE ALARM WITH INTERCONNECT
Apr 16th, 2009 by admin

£28.98 inc postage

y4
Y4-NEW WIRED IONISATION SMOKE ALARM WITH INTERCONNECT

    Interconnect up to 12 other alarms (Ionisation alarms Ei 100C ) – when one senses smoke all alarm. Helps ensure warning will be heard throughout the house.
    Main Features:
    Interconnect up to 12 other alarms
    High sensitivity – responds to all standard fires

    Dual ionisation chamber – quick response to fast flaming fires
    Mains powered
    Built in sounder to give a minimum sound output of 85dB(A) at 3m
    Bleeps every 40 seconds when battery needs replacing
    Easily installed – no wiring
    Test Button simulates smoke – use to check performance at least monthly
    Installation:
    Pull cover open at Tab. Remove cover from base by separating at rear snap-in hinges

    Place the base on ceiling or wall exactly where you want to mount the unit. With a pencil, mark the location of the screw holes

    Taking care to avoid any electrical wiring in the ceiling or wall, drill a hole through the centres of the marked locations. Push the plastic screw anchors provided into the drilled holes. Screw in firmly

    With a pencil, write the date of battery installation on the inside of the cover to remind you when to replace the battery. Lift battery from battery holder, and snap battery connectors to battery. They fit together only one way. Gently push battery into battery holder. To close the cover match up snap-in hinges and gently press together until base and cover snap together

    All models are fitted with a warning flag which pops up when the battery is removed. This prevents the cover from closing when there is no battery in the unit. When the battery is being installed or changed, this flag must be held down while gently pushing the battery into the battery holder